RADIX WIRE CO
Sort by:Recommended
16-1C STR NPC MG - NO MARKING MICA GLS/FBR GLS BRD NATUR 600450C UL5335/510
Specifications:
Conductor Count 1 CONDUCTOR Conductor Material NICKEL PLATED COPPER Conductor Size 16 AWG Conductor Type STRANDED Earth/Ground Wires NO Insulation Material MICA-TRANSPARENT SILICATE Jacket Material GL-BRD-GLASS BRAID Product Type HIGH TEMP Screen/Shield UNSHIELDED Standards UL Voltage Range 600V UNSPSC Code 26121539 18-2C SOL BC FPL-LS CM 2-HR CI/CIC DUAL RATED CABLE UL2196 105C 300V
Specifications:
Conductor Count 2 CONDUCTORS Conductor Material BARE COPPER Conductor Size 18 AWG (AMERICAN WIRE GAUGE) Conductor Type SOLID CONDUCTOR Fire Rating GENERAL PURPOSE Insulation Material LSZH-LOW SMOKE ZERO HALOGEN Jacket Material LSZH-LOW SMOKE ZERO HALOGEN NEC Rating FPLR-CI Screen/Shield Type BRAID SHIELDED Screen/Shield NO Shield Construction SPECIAL CONSTRUCTION UNSPSC Code 26121613 16-2C SOL BC FPL-LS CM 2-HR CI/CIC DUAL RATED CABLE UL2196 105C 300V
COMPLIANCE:
- UL 1424 Listed FPLR/FPLR-CI (dual-rated) for Power-Limited Fire Alarm Circuits. Riser Rated.300V/105°C classified.
- UL / CAN (ULC) Certified to UL 2196 2-hour fire rating in FHIT / FHIT7 28C.
- CSA Certified FAS90; CSA Std. C22.2 No. 208-14 FT4-ST1.
- UL Certified 2-hour fire rating as FPLR-CI for Free Air installed per NEC code.
- UL 444 Listed "CMR/CMR-CI" as Communications Cable.
- Fire alarm circuit integrity, emergency systems, and healthcare facilities (NEC Articles 760, 700 & 517).
- Meets National Fire Protection Code (NFPA 70 & 72) fire alarm survivability circuit requirements.
- Meets National Fire Protection Code (NFPA 130 & 502) fire alarm survivability circuit requirements.
- Compliance tested to UL 1424 as suitable for use in applications requiring wet rating.
- Tested for Sunlight Resistance in compliance with UL 2556 requirements.
- Suitable for 2-hour certified fire-resistive applications in EMT, IMC, or Phenolic conduit systems.
- UL Listed File No. E-241484. UL Fire Directory R-21213.
- Splice Allowance.
16-2C SOL BC FPL-LS CM 2-HR CI/CIC DUAL RATED SHIELDED UL2196 105C 300V
Certified to the harsh requirements of the UL2196 Test for Fire Resistive Cables, the DuraLife II Dual Rated CIC /CI cables ensure the two-hour operation of critical systems in the event of a fire. The dual rating design offers the most versatility in meeting code survivability requirements in both in-conduit and free-air installation scenarios.
16-2C SOL BC FPL-LS CM 2-HR CI/CIC DUAL RATED SHIELDED UL2196 105C 300V
Certified to the harsh requirements of the UL2196 Test for Fire Resistive Cables, the DuraLife II Dual Rated CIC /CI cables ensure the two-hour operation of critical systems in the event of a fire. The dual rating design offers the most versatility in meeting code survivability requirements in both in-conduit and free-air installation scenarios.