MAXIM77 Altronix Access Power Controller 16 Fuse Protected Outputs

        MAXIM77 Altronix Access Power Controller 16 Fuse Protected Outputs

        SKU: WECMAXIM77
        Altronix
        SKU: WECMAXIM77
        Altronix offers a complete line of Safety and Security, Fire, CCTV, Access, Nurse Call, and automation product. The MAXIM77, This unit distributes and switches power to access control systems and accessories. It converts a 115VAC 60Hz input into sixteen (16) independently controlled 24VDC fuse protected outputs. These power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs. Built-in charger for sealed lead acid or gel type batteries. Automatic switch over to stand-by battery when AC fails. Zero voltage drop when unit switches over to battery backup (AC failure condition). Short circuit and thermal overload protection with auto reset. AC input and DC output LED indicators. AC fails supervision (form "C" contact). Battery fail and battery presence supervision (form "C" contact). Sixteen (16) Access Control System trigger inputs. Sixteen (16) independently controlled fuse protected outputs. Sixteen (16) auxiliary power outputs (un switched) (outputs are rated 3.5 amp). ACM8 board's main fuse is rated @ 10 amp. Red LEDs indicate outputs are triggered (relays energized). Fire Alarm disconnects (latching or non-latching) is individually selectable for any or all of the Sixteen (16) outputs. Alarm output relay indicates that FACP input is triggered (form “C” contact rated @ 1 amp 28VDC not evaluated by UL). Green LED indicates FACP disconnect is triggered. Must be a reseller to purchase this product. The Product MADE IN THE U.S.A. and the company is providing lifetime warranty for the product. Altronix offers OEM design and manufacturing services to create custom electronics for commercial and industrial applications and the power products and peripherals, feature the quality, reliability and unparalleled customer support that have been associated with Altronix for over 30 years.
          • 25% less
          Market price:$1286.00 save $321.50
        • $964.50
         
        OR
        Altronix offers a complete line of Safety and Security, Fire, CCTV, Access, Nurse Call, and automation product. The MAXIM77, This unit distributes and switches power to access control systems and accessories. It converts a 115VAC 60Hz input into sixteen (16) independently controlled 24VDC fuse protected outputs. These power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs. Built-in charger for sealed lead acid or gel type batteries. Automatic switch over to stand-by battery when AC fails. Zero voltage drop when unit switches over to battery backup (AC failure condition). Short circuit and thermal overload protection with auto reset. AC input and DC output LED indicators. AC fails supervision (form "C" contact). Battery fail and battery presence supervision (form "C" contact). Sixteen (16) Access Control System trigger inputs. Sixteen (16) independently controlled fuse protected outputs. Sixteen (16) auxiliary power outputs (un switched) (outputs are rated 3.5 amp). ACM8 board's main fuse is rated @ 10 amp. Red LEDs indicate outputs are triggered (relays energized). Fire Alarm disconnects (latching or non-latching) is individually selectable for any or all of the Sixteen (16) outputs. Alarm output relay indicates that FACP input is triggered (form “C” contact rated @ 1 amp 28VDC not evaluated by UL). Green LED indicates FACP disconnect is triggered. Must be a reseller to purchase this product. The Product MADE IN THE U.S.A. and the company is providing lifetime warranty for the product. Altronix offers OEM design and manufacturing services to create custom electronics for commercial and industrial applications and the power products and peripherals, feature the quality, reliability and unparalleled customer support that have been associated with Altronix for over 30 years. A leading global provider of power and transmission technologies for professional security system applications, Altronix develops innovative solutions that integrate disparate infrastructure and maximize overall performance and efficiency. New additions to our 2015 line include adaptive transmission products that facilitate network connectivity and system expansion, utilizing legacy, as well as state of the art system technology.

        Footer navigation